Piezo Cylinders Piezo Tube Piezoelectric Cylinders PZT-5
Our company has been 11 years since its inception, mature technology, stable performance, preferential prices, with a monthly production capacity of more than 200000 pieces, and annual ISO9000 quality system certification, welcome to contact us!
The conversion efficiency is related to transducer material, vibration form, structure of mechanical vibration system (including support mechanism) and working frequency. Therefore, the problem of ultrasonic transmitter is solved. There are two kinds of materials for piezoelectric ceramic transducer: magnetostrictive metal and piezoelectric ceramic. Piezoelectric ceramic transducer is a kind of electronic ceramic material with piezoelectric characteristics. The main difference between piezoelectric ceramic transducer and typical piezoelectric quartz crystal without ferroelectric component is that the crystal phase of its main component is ferroelectric grain. Because ceramics are polycrystalline aggregates with randomly oriented grains, the spontaneous polarization vector of each ferroelectric grain is also lost.
If the transducer made of this kind of piezoelectric ceramic is put into the water, under the action of sound wave, electric charge will be induced at both ends of the transducer, which is the acoustic receiver. In addition, the piezoelectric effect is reversible. If the alternating electric field is applied to the piezoelectric ceramic chip, the ceramic plate will become thinner and thicker from time to time, and generate vibration and sound waves. The piezoelectric ceramics must be polarized in a strong dc electric field after firing, and the end faces are subjected to multiple electrodes, so that the polarization vector of the original disordered orientation is preferentially oriented to the direction of the electric field. After the electric field is eliminated, the piezoelectric ceramics after polarization treatment will maintain a certain macro residual polarization strength, so that the ceramics have a certain pressure.

spec |
Dimension (mm) |
Radial frequency (KHz) |
Capacitance (pf) |
Dielectric dissipation factor tanδ(%) |
Electromechanical coupling coefficient (Kr) |
Impedance Zr(Ω) |
Thickness frequency (KHz) |
PU-PC25103 | Φ25×Φ10×3 | 66.4 | 1240±12.5% | ≤0.3 | ≥0.46 | ≤15 | 683±5% |
PU-PC225104 | Φ25×Φ10×4 | 66.4 | 930±12.5% | ≤0.3 | ≥0.46 | ≤15 | 512±5% |
PU-PC40155 | Φ40×Φ12×5 | 45.9 | 2070±12.5% | ≤0.3 | ≥0.46 | ≤15 | 410±5% |
PU-PC40155 | Φ40×Φ15×5 | 42.2 | 1960±12.5% | ≤0.3 | ≥0.46 | ≤15 | 323±5% |
PU-PC40176 | Φ40×Φ17×6 | 40.5 | 1555±12.5% | ≤0.3 | ≥0.46 | ≤15 | 341±5% |
PU-PC40205 | Φ40×Φ20×5 | 37.9 | 1700±12.5% | ≤0.3 | ≥0.47 | ≤15 | 410±5% |
PU-PC50206 | Φ50×Φ20×6 | 33.2 | 2490±12.5% | ≤0.3 | ≥0.46 | ≤15 | 341±5% |
PU-PC501765 | Φ50×Φ17×6.5 | 34.8 | 2430±12.5% | ≤0.3 | ≥0.46 | ≤15 | 315±5% |
PU-PC50236 | Φ50×Φ23×6 | 31.2 | 2340±12.5% | ≤0.3 | ≥0.47 | ≤15 | 341±5% |
PU-PC50276 | Φ50×Φ27×6 | 29.3 | 2100±12.5% | ≤0.3 | ≥0.47 | ≤15 | 341±5% |
PU-PC603010 | Φ60×Φ30×10 | 25.3 | 1922±12.5% | ≤0.3 | ≥0.47 | ≤18 | 205±5% |
TAG ultrasonic: Piezoelectric Cylinder Underwater Piezoelectric Transducer Piezo Ceramic Tube 90 KHz China Tube Piezoelectric Ceramic
Piezo Cylinders Piezo Tube Piezoelectric Cylinders PZT-5